Mon–Sat 9:00–19:00 (UTC+8)

Custom Artificial Ficus Canopy Tree for Hotel Atriums & Lobbies

Application: Hotel Atriums & Lobbies · Custom heights 3–9 m

We build custom artificial ficus canopy trees for hotel atriums and lobbies — 3–9 m specimens, NFPA 701 fire-retardant treatment available as an option, engineered per project. Atrium trees must read from three floors up, pass a fire inspection, and still look right in a guest's photo years later. We engineer specimens from 2 to 12 m that do all three, delivered and installed worldwide.

  • Trunk sculpted as a column or an arched lattice
  • Canopy diameter specified to cover a given seat count
  • Optional integrated LED uplighting
Technical Specifications

Ficus Canopy Tree Build Spec

Unit Size3–9 m, canopy 2.5–6 m
Height Range2–10 m (customizable to your photos or drawings)
TrunkSculpted fiberglass over galvanized steel, formed as a single column or an arched lattice.
FoliagePE and PU materials; optional UV-resistant finish for outdoor use.
BaseSteel plate base — set in concrete or installed in a planter.
Fire RetardancyOptional NFPA 701 / BS 5867.
MaintenanceNo routine maintenance — no watering, feeding or leaf cleanup.
Lead TimeStandard builds 25–35 days; custom builds 45–60 days.
Sizing & Compliance for Hotel Atriums & Lobbies

What This Venue Needs

Sizing

Specimens run 2–12 m; above the height that fits a container upright they are engineered knock-down and assembled in place, with rigging notes for your contractor.

Compliance & Anchoring

NFPA 701 fire-retardant foliage is available as an option, with EN 13501 B-s1,d0 available for EU hotels. Base-plate loading and anchoring details ship with every large build.

Project Specification

Ficus Canopy Tree specified for Hotel Atriums & Lobbies

Ficus Canopy Tree (SKU VW-FIC-450) is quoted at 3–9 m for hotel atriums and lobbies, against the 2–12 m height band this venue is engineered for. The review pack is assembled for a hotel operator, not a single buyer.

Buying parameters for this venue

Reference SKUVW-FIC-450
Species height range3–9 m
Venue height band2–12 m
Base & fixingKnock-down assembly · Rigging notes supplied
DocumentationFor VW-FIC-450: NFPA 701 fire-retardant foliage is available as an option, with EN 13501 B-s1,d0 available for EU hotels. Base-plate loading and anchoring details ship with every large build.
Finished lounge scheme, Germany project
Finished lounge scheme, Germany project

Installation, materials & documentation

Installation is scheduled around guest access: the crown arrives in numbered rings and the trunk as engineered knock-down parts that bolt to the base plate inside a closed work zone, and the area reopens only after the anchoring check is signed off.

The submittal pack carries the foliage fire report, base-plate loading and the sprinkler-clearance drawing. Housekeeping receives a branch-ring map so reachable sections can be lifted off for cleaning without closing the lobby.

Buyer Questions

Ordering & Specification FAQs

What buyers ask when specifying ficus canopy trees for hotel atriums and lobbies — MOQ, lead time and this venue's requirements.

MOQ is project-based rather than per-SKU, and a single ficus canopy at 3–9 m with a 2.5–6 m spread can be quoted on its own. Canopy diameter is set against a seat count, so each tree is priced on its own coverage rather than on a catalogue line — mixed species and mixed sizes are quoted together.

25–35 days for standard builds, and 45–60 days for custom builds. Lead time starts from approved drawings rather than from the enquiry, and the canopy diameter and trunk form (column or arched lattice) are both drawn items — approving them together is what keeps the build on schedule.

Yes — NFPA 701 fire-retardant foliage is available as an option on every tree, and EN 13501 B-s1,d0 is available for EU projects, with batch test reports archived against your order.

Yes. Crown scale and trunk detailing are drawn to the sight lines of your specific atrium, so the tree looks right at 3 m and at 10 m alike.

Yes — 3–9 m with a canopy diameter specified against a seat count, and the trunk sculpted as either a single column or an arched lattice. Foliage density is set for the sight lines below the crown, and optional integrated LED uplighting is specified at order stage rather than added on site.

Configure This Tree for Your Hotel Atriums & Lobbies

Height, trunk finish, foliage density, planter and base plate — tell us the venue and we'll send CAD options within 12 business hours.

WhatsApp an Engineer All Solutions